File nvme-cli.spec of Package nvme-cli.11415
#
# spec file for package nvme-cli
#
# Copyright (c) 2019 SUSE LINUX GmbH, Nuernberg, Germany.
#
# All modifications and additions to the file contributed by third parties
# remain the property of their copyright owners, unless otherwise agreed
# upon. The license for this file, and modifications and additions to the
# file, is the same license as for the pristine package itself (unless the
# license for the pristine package is not an Open Source License, in which
# case the license is the MIT License). An "Open Source License" is a
# license that conforms to the Open Source Definition (Version 1.9)
# published by the Open Source Initiative.
# Please submit bugfixes or comments via https://bugs.opensuse.org/
#
Name: nvme-cli
Version: 1.5
Release: 0
Summary: NVM Express user space tools
License: GPL-2.0-only
Group: Hardware/Other
Url: https://github.com/linux-nvme/nvme-cli
Source: %{name}-v%{version}.tar.gz
Source2: nvme-cli-rpmlintrc
BuildRequires: asciidoc
BuildRequires: libuuid-devel
BuildRequires: xmlto
BuildRequires: pkgconfig(libudev)
BuildRequires: pkgconfig(systemd)
BuildRequires: pkgconfig(udev)
%ifarch x86_64 aarch64 i586
Requires(post): dmidecode
%endif
BuildRoot: %{_tmppath}/%{name}-%{version}-build
Patch1: 0001-nvme-cli-add-NetApp-plugin.patch
Patch2: 0002-nvme-cli-add-netapp-smdevices-man-page.patch
Patch3: 0003-get-log-Make-log-identifier-a-required-parameter.patch
Patch4: 0004-Documentation-add-manpage-entry-for-connect-s-ctrl-l.patch
Patch5: 0005-fabrics-add-option-to-supply-keep-alive-timeout-for.patch
Patch6: 0006-fabrics-add-ctrl-loss-tmo-to-connect-all.patch
Patch7: 0007-nvme-vendor-Add-get-log-LSP-LSO-fields-from-1.3-spec.patch
Patch8: 0008-nvme-cli-Implement-nvme_get_log13.patch
Patch9: 0009-nvme-cli-Add-support-of-unsigned-long-long-to-json-r.patch
Patch10: 0010-nvme-cli-add-support-of-RAE.patch
Patch11: 0011-nvme-cli-add-minimal-ana-log-page-support.patch
Patch12: 0012-nvme-cli-add-ana-log-documentation.patch
Patch13: 0013-nvme-discover-sanitize-options.patch
Patch14: 0014-Fix-double-free-in-list_subsys.patch
Patch15: 0015-Log-error-incase-of-failure-in-get_nvme_subsystem_in.patch
Patch16: 0016-nvme-cli-move-print-function-to-nvme-print.patch
Patch17: 0017-nvme-cli-show-partial-results-if-controller-fails-du.patch
Patch19: 0019-nvme-discover-Retry-discovery-log-if-the-generation-.patch
Patch20: 0020-nvme-cli-fabrics-Fix-passing-host_traddr-for-all-tra.patch
Patch21: 0021-fabrics-write-ctrl_loss_tmo-to-fabrics-device-on-con.patch
Patch22: 0022-fabrics-write-keep-alive-timeout-to-fabrics-device-o.patch
Patch23: 0023-Fix-print-format-specifier-for-64-bit.patch
Patch24: 0024-nvme-ana-log-fixup-compiler-warning-in-show_ana_log.patch
Patch25: 0025-fabrics-make-some-arguments-integers.patch
Patch26: 0026-fabrics-don-t-fail-empty-discovery-log-page.patch
Patch27: 0027-nvme-commonize-subsystems-info-in-a-helper.patch
Patch28: 0028-nvme-ioctl-retrieve-log-pages-in-4k-chunks.patch
Patch29: 0029-nvme-discover-Re-check-generation-counter-after-log-.patch
Patch30: 0030-nvme-fixup-ANA-group-descriptor-offset.patch
Patch31: 0031-nvme-introduce-get_nvme_ctrl_attr.patch
Patch32: 0032-nvme-print-out-controller-state-for-list-subsys.patch
Patch33: 0033-nvme-list-subsys-Add-device-name-argument-and-print-.patch
Patch34: 0034-fabrics-allow-nr_io-write-poll_queues-and-queue-size.patch
Patch35: 0035-fabrics-do-not-use-queue_size-and-nr_io_queues-for-d.patch
Patch36: 0036-fabrics-mask-out-invalid-options-during-discovery.patch
Patch37: 0037-nvme-Document-Q-and-i-for-discovery-and-connect-all.patch
Patch38: 0038-nvme-cli-add-netapp-ontapdevices-command.patch
Patch39: 0039-nvme-cli-add-netapp-ontapdevices-man-page.patch
Patch40: 0040-nvme-cli-Increase-size-of-ONTAP-namespace-path-varia.patch
Patch41: 0041-nvme-vendor-fixup-c99-declaration-in-huawei-plugin.patch
Patch42: 0042-nvme-cli-fix-fc-trtype-string.patch
Patch43: 0043-flush-Use-device-NSID-if-issuing-through-block-devic.patch
Patch100: 0100-nvme_fc-auto-connect-scripts.patch
Patch101: 0101-71-nvme-iopolicy-netapp.rules-add-default-rules-for-.patch
Patch102: 0102-Add-nvmefc-connect.target.patch
Patch103: 0103-Change-service-to-type-simple.patch
Patch104: 0104-nvme-cli-Fix-documentation-syntax-and-typo.patch
Patch105: 0105-nvme-cli-Check-for-sysfs-interface-before-NVMe-disco.patch
Patch106: 0106-nvme-cli-Update-nvme-connect-all-man-page.patch
Patch107: 0107-nvme-cli-add-default-IO-policy-rule-for-NetApp-E-Ser.patch
Patch108: 0108-nvme-cli-Rename-udev-rule-for-ONTAP-controller.patch
Patch109: 0109-nvme-cli-Add-script-to-determine-host-NQN.patch
%description
NVM Express (NVMe) is a direct attached storage interface. The
nvme-cli package contains core management tools with minimal
dependencies.
%package -n nvme-cli-regress-script
Summary: A small script to test the nvme binary for regressions
Group: Hardware/Other
Requires: nvme-cli
%description -n nvme-cli-regress-script
A small shell script to test the nvme binary for regressions. It requires an
NVMe device for testing purposes. Do NOT use in a production environment.
%prep
%setup -q -n %{name}-v%{version}
%patch1 -p1
%patch2 -p1
%patch3 -p1
%patch4 -p1
%patch5 -p1
%patch6 -p1
%patch7 -p1
%patch8 -p1
%patch9 -p1
%patch10 -p1
%patch11 -p1
%patch12 -p1
%patch13 -p1
%patch14 -p1
%patch15 -p1
%patch16 -p1
%patch17 -p1
%patch19 -p1
%patch20 -p1
%patch21 -p1
%patch22 -p1
%patch23 -p1
%patch24 -p1
%patch25 -p1
%patch26 -p1
%patch27 -p1
%patch28 -p1
%patch29 -p1
%patch30 -p1
%patch31 -p1
%patch32 -p1
%patch33 -p1
%patch34 -p1
%patch35 -p1
%patch36 -p1
%patch37 -p1
%patch38 -p1
%patch39 -p1
%patch40 -p1
%patch41 -p1
%patch42 -p1
%patch43 -p1
%patch100 -p1
%patch101 -p1
%patch102 -p1
%patch103 -p1
%patch104 -p1
%patch105 -p1
%patch106 -p1
%patch107 -p1
%patch108 -p1
%patch109 -p1
%build
echo %{version} > version
make CFLAGS="%{optflags}" PREFIX=%{_prefix} %{?_smp_mflags} all
# nvme-cli-regress-script subpackage: remove make and install steps
sed -i '/make.*/d' regress
%install
make PREFIX=%{_prefix} DESTDIR=%{buildroot} install-bin install-man %{?_smp_mflags}
install -m 644 -D /dev/null %{buildroot}%{_sysconfdir}/nvme/hostnqn
install -m 644 -D completions/bash-nvme-completion.sh %{buildroot}%{_datadir}/bash_completion/completions/nvme
install -m 644 -D nvme-fc-autoconnect/70-nvmefc-autoconnect.rules %{buildroot}%{_udevrulesdir}/70-nvmefc-autoconnect.rules
install -m 644 -D nvme-fc-autoconnect/nvmefc-boot-connections.service %{buildroot}%{_unitdir}/nvmefc-boot-connections.service
install -m 644 -D nvme-fc-autoconnect/nvmefc-connect@.service %{buildroot}%{_unitdir}/nvmefc-connect@.service
install -m 644 -D nvme-fc-autoconnect/nvmefc-connect.target %{buildroot}%{_unitdir}/nvmefc-connect.target
install -m 644 -D scripts/71-nvme-iopolicy-netapp-ONTAP.rules %{buildroot}%{_udevrulesdir}/71-nvme-iopolicy-netapp-ONTAP.rules
install -m 644 -D scripts/71-nvme-iopolicy-netapp-E-Series.rules %{buildroot}%{_udevrulesdir}/71-nvme-iopolicy-netapp-E-Series.rules
%ifarch x86_64 aarch64 i586
install -m 744 -D scripts/det-hostnqn.sh %{buildroot}%{_sbindir}/nvme-det-hostnqn
%endif
# for subpackage nvme-cli-regress-script:
install -m 744 -D regress %{buildroot}%{_sbindir}/nvme-regress
%define services nvmefc-boot-connections.service nvmefc-connect.target
%pre
%service_add_pre %services nvmefc-connect@.service
%post
%ifarch x86_64 aarch64 i586
if [ ! -s %{_sysconfdir}/nvme/hostnqn ]; then
%{_sbindir}/nvme-det-hostnqn > %{_sysconfdir}/nvme/hostnqn
fi
%endif
if [ ! -s %{_sysconfdir}/nvme/hostnqn ]; then
%{_bindir}/echo "Generating random host NQN."
%{_sbindir}/nvme gen-hostnqn > %{_sysconfdir}/nvme/hostnqn
fi
if [ ! -s %{_sysconfdir}/nvme/hostid ]; then
%{_bindir}/uuidgen > %{_sysconfdir}/nvme/hostid
fi
%service_add_post %services nvmefc-connect@.service
%preun
%service_del_preun -f %services
%postun
%service_del_postun %services
%posttrans
if [ -f /sys/class/fc/fc_udev_device/nvme_discovery ]; then
%{_bindir}/echo add > /sys/class/fc/fc_udev_device/nvme_discovery
fi
%files
%defattr(-,root,root)
%doc README.md LICENSE
%{_sbindir}/nvme
%ifarch x86_64 aarch64 i586
%{_sbindir}/nvme-det-hostnqn
%endif
%{_mandir}/man1/nvme*.1*
%dir %{_sysconfdir}/nvme/
%dir %{_datadir}/bash_completion
%dir %{_datadir}/bash_completion/completions/
%{_datadir}/bash_completion/completions/nvme
%{_udevrulesdir}/70-nvmefc-autoconnect.rules
%{_udevrulesdir}/71-nvme-iopolicy-netapp-ONTAP.rules
%{_udevrulesdir}/71-nvme-iopolicy-netapp-E-Series.rules
%{_unitdir}/nvmefc-boot-connections.service
%{_unitdir}/nvmefc-connect@.service
%{_unitdir}/nvmefc-connect.target
%ghost %{_sysconfdir}/nvme/hostnqn
%ghost %{_sysconfdir}/nvme/hostid
%files -n nvme-cli-regress-script
%{_sbindir}/nvme-regress
%changelog