ICC compatible color management system

Edit Package argyllcms
http://www.%{name}.com/

The Argyll color management system supports accurate ICC profile creation for
scanners, CMYK printers, film recorders and calibration and profiling of
displays.

Spectral sample data is supported, allowing a selection of illuminants observer
types, and paper fluorescent whitener additive compensation. Profiles can also
incorporate source specific gamut mappings for perceptual and saturation
intents. Gamut mapping and profile linking uses the CIECAM02 appearance model,
a unique gamut mapping algorithm, and a wide selection of rendering intents. It
also includes code for the fastest portable 8 bit raster color conversion
engine available anywhere, as well as support for fast, fully accurate 16 bit
conversion. Device color gamuts can also be viewed and compared using a VRML
viewer.

Refresh
Refresh
Source Files
Filename Size Changed
19-color.fdi 0000004859 4.75 KB
Argyll_V3.2.0_src.zip 0014690714 14 MB
ajam-2.5.2-1.3.3.tgz 0000258260 252 KB
ajam-gcc14.patch 0000000688 688 Bytes
ajam-include.patch 0000001164 1.14 KB
argyllcms.changes 0000038353 37.5 KB
argyllcms.spec 0000005077 4.96 KB
color-device-file.policy 0000000658 658 Bytes
Latest Revision
Ana Guerrero's avatar Ana Guerrero (anag+factory) accepted request 1177369 from Antonio Teixeira's avatar Antonio Teixeira (ateixeira) (revision 34)
- Update to 3.2.0:
  * Added extra diagnostics to printcal.
  * Added colprof -nI option, that adds inverse gamut mapping to Perceptual and
    Saturation A2B tables, if they are being created. This is not recommended for
    source profiles, since it handicaps true gamut mapping, but may be a workaround
    to faulty Adobe Lightroom BPC for Perceptual intent in output profiles.
  * Added error message for ColorMunki spectro sensor internal cable being
    disconnected.
  * Fixed bug in Appearance B2A conversion that appeared in V3.0 release.
  * Fixed crash in chartread strip reading when given faulty .ti2 file.
  * Tweaked i1d3 AIO adaptive integration time to reduce measure time to be more
    comparable to just using Rev A commands.
  * Re-worked ARGYLL_NOT_INTERACTIVE stdin to work much better on MSWin when
    connected to a pipe. Removed code that empties stdin before expecting use input
    when ARGYLL_NOT_INTERACTIVE.
  * Fixed OS X dispwin -c etc.
  * Fixed colprof IGNORE_DISP_ZEROS heuristic so that it doesn't reject OLED red
    measurements that have a Z value of 0.0.
  * Added -H option to colprof to allow setting the charTargetTag to given string,
    rather than automatically filling with .ti3 data.
  * Changed instrument monitoring thread debug messages to only be shown on -D9, so
    they don't interfere with messages shown at -D8.
Comments 0
openSUSE Build Service is sponsored by