This update for mdadm fixes the following issues:
- Detail: show correct raid level when the array is inactive. (jsc#SLE-13700)
- Don't create bitmap for raid5 with journal disk. (jsc#SLE-13700)
- Monitor: refresh mdstat fd after select. (jsc#SLE-13700)
- Monitor: stop notifing about containers. (jsc#SLE-13700)
- mdmonitor: set small delay once. (jsc#SLE-13700)
- Check if other Monitor instance running before fork. (jsc#SLE-13700)
- Super1: allow RAID0 layout setting to be removed. (jsc#SLE-13700)
- Detail: fix segfault during IMSM raid creation. (jsc#SLE-13700)
- Create.c: close mdfd and generate uevent. (jsc#SLE-13700)
- imsm: remove redundant calls to imsm_get_map. (jsc#SLE-13700)
- Monitor: don't use default modes when creating a file. (jsc#SLE-13700)
- imsm: limit support to first NVMe namespace. (jsc#SLE-13700)
- mdadm: Unify forks behaviour. (jsc#SLE-13700)
- mdadm/Detail: show correct state for clustered array. (jsc#SLE-13700)
- Make target to install binaries only. (jsc#SLE-13700)
- udev: start grow service automatically. (jsc#SLE-13700)
This update was imported from the SUSE:SLE-15-SP1:Update update project.
-
Submitted by
Coly Li (colyli)