File _patchinfo of Package patchinfo.4353
<patchinfo incident="4353"> <issue id="1016795" tracker="bnc">sapconf/tuned: documentation and alignment of influenced parameters and settings</issue> <issue id="1025824" tracker="bnc">saptune causing performance drop and turbostat not to function on SLES12 SP2</issue> <issue id="983454" tracker="bnc">sapconf to start uuidd service after installation</issue> <issue id="1027411" tracker="bnc">sapconf - integer overflow in all numeric tuning options</issue> <issue id="320783" tracker="fate"/> <category>recommended</category> <rating>low</rating> <packager>guohouzuo</packager> <description> This update for sapconf fixes the following issues: - Use arbitrary precision calculator rather than bash's built-in integer calculator to calculate parameter values. This fixes potential integer overflow issues. (bsc#1027411) - Apply tuning technique of Netweaver in HANA profile too. (bsc#1016795) - Remove "force_latency=1" from HANA's configuration, so that CPUs are no longer kept busy when idling. (bsc#1025824) - Start uuidd.socket as soon as the package is installed. (bsc#983454) - Control uuidd as a step of the tuning process. (bsc#983454) - Recommend installation of tuned. (fate#320783) </description> <summary>Recommended update for sapconf</summary> </patchinfo>