<patchinfo incident="4269">
<issue id="996230" tracker="bnc">[s390x] Upgrade from SP1-GM + HA to SP2-RC2 +: Failed to start Corosync Cluster engine</issue>
<issue id="1051638" tracker="bnc">corosync failed to start when /etc/hosts having IPv6 address</issue>
<issue id="1032634" tracker="bnc">corosync: assert(sender_node != NULL) fails after tearing down a network interface</issue>
<issue id="1047862" tracker="bnc">some errors in spec file</issue>
<issue id="1043045" tracker="bnc">some fixes from upstream</issue>
<issue id="1037226" tracker="bnc">A Corosync process is not locked in memory</issue>
<issue id="1030437" tracker="bnc">Changing the pre-upgrade role for node failed</issue>
<issue id="1023959" tracker="bnc">corosync logging priority takes no effect</issue>
<issue id="1047876" tracker="bnc">type error in corosync.spec</issue>
<issue id="1060767" tracker="bnc">wrong "service_del_postun corosync.service"</issue>
<category>recommended</category>
<rating>moderate</rating>
<packager>BinLiu</packager>
<description>
This update for corosync provides the following fixes:
- Don't terminate with assertion error after a network interface goes down. (bsc#1032634)
- Don't fail to start when /etc/hosts contains IPv6 addresses. (bsc#1051638)
- Ensure corosync processes are memory locked. (bsc#1037226)
- Prefer nodelist over bindnetaddr when both are available. (bsc#1030437)
- Set initial logging priority to a lower value to allow log filters configured in
corosync.conf to be applied. (bsc#1023959)
- Fix a failure when starting Corosync Cluster engine. (bsc#996230)
</description>
<summary>Recommended update for corosync</summary>
</patchinfo>