File bsc#1085515-pacemaker-Pacemaker-Explained-symmetrical-defaults-to-false-for-serialize-orders.patch of Package pacemaker.14737
commit 11082f3319c4649416ce5ecd1c5523b4f2cd3a8b
Author: Gao,Yan <ygao@suse.com>
Date: Sat Mar 24 12:25:40 2018 +0100
Doc: Pacemaker Explained: "symmetrical" defaults to "false" for serialize orders
diff --git a/doc/Pacemaker_Explained/en-US/Ch-Constraints.txt b/doc/Pacemaker_Explained/en-US/Ch-Constraints.txt
index 69e8fb001..4477c64c7 100644
--- a/doc/Pacemaker_Explained/en-US/Ch-Constraints.txt
+++ b/doc/Pacemaker_Explained/en-US/Ch-Constraints.txt
@@ -308,9 +308,10 @@ indexterm:[kind,Ordering Constraints]
indexterm:[Constraints,Ordering,kind]
|symmetrical
-|TRUE
+|TRUE for +Mandatory+ and +Optional+ kinds. FALSE for +Serialize+ kind.
|If true, the reverse of the constraint applies for the opposite action (for
example, if B starts after A starts, then B stops before A stops).
+ +Serialize+ orders cannot be symmetrical.
indexterm:[symmetrical,Ordering Constraints]
indexterm:[Ordering Constraints,symmetrical]