Sign Up
Log In
Log In
or
Sign Up
Places
All Projects
Status Monitor
Collapse sidebar
SUSE:SLE-12-SP5:GA
patchinfo.1626
_patchinfo
Overview
Repositories
Revisions
Requests
Users
Attributes
Meta
File _patchinfo of Package patchinfo.1626
<patchinfo incident="1626"> <issue id="971334" tracker="bnc">Can't start clvmd resource in HA cluster under openSUSE 20160307 Tumbleweed</issue> <issue id="970439" tracker="bnc">pacemaker lvm resource agent must not start if lvmetad is enabled</issue> <issue id="969310" tracker="bnc">SLES 12 SP1 - x86_64: pvchange returns with exit code 5 if another volume group is exported</issue> <issue id="963427" tracker="bnc">lvm activation failed on boot if locking_dir is on /var/lock/lvm</issue> <issue id="960744" tracker="bnc">pvcreate returns confusing error message</issue> <issue id="960044" tracker="bnc">Broken symlink in systemd configuration - lvm2-lvmetad.socket</issue> <issue id="966183" tracker="bnc">pvchange writes to stderr output but exit code is 0</issue> <issue id="955529" tracker="bnc">Unable to correct lvscan from finding the device twice</issue> <issue id="940298" tracker="bnc">Error message printed when lvremove snap lv</issue> <category>recommended</category> <rating>moderate</rating> <packager>wanglh</packager> <description> This update for lvm2 fixes the following issues: - Fix clvmd.ocf and cmirrord to remove "-d" option for cmirrord. (bsc#971334) - Fix clvmd.ocf to add lvmconf --enable-cluster before starting daemon when locking_type is not 3 or use_lvmetad is 1. (bsc#970439) - Fix pvchange returning with exit code 5 if another volume group which is not related to the PVs is exported. (bsc#969310) - Omit some warning messages from pvcreate. (bsc#966183) - Change default locking_dir from "/var/lock/lvm" back to "/run/lvm/lock". (bsc#963427) - Improve pvcreate's error messages to be more informative. (bsc#960744) - Add 'Also=lvm2-lvmetad.socket' to '[Install]' section of lvm2-lvmetad.service to trigger removal of the former when the latter is disabled. (bsc#960044) - Remove verbose message when re-scanning devices. (bsc#955529) - Do not output error message inside retry loops to avoid noisy error message in case of remove failure because device is busy. (bsc#940298) </description> <summary>Recommended update for lvm2</summary> </patchinfo>
Locations
Projects
Search
Status Monitor
Help
OpenBuildService.org
Documentation
API Documentation
Code of Conduct
Contact
Support
@OBShq
Terms
openSUSE Build Service is sponsored by
The Open Build Service is an
openSUSE project
.
Sign Up
Log In
Places
Places
All Projects
Status Monitor