File _patchinfo of Package patchinfo.14071

<patchinfo incident="14071">
  <issue tracker="bnc" id="1156040">[Intel SLES 15 SP1 bug][VROC] mdadm cannot enumerate more then 6 OpROMs</issue>
  <issue tracker="bnc" id="1162479">Failure to create RAID0 or LVM when installing on two disks</issue>
  <issue tracker="bnc" id="1129900">Raid0 change to Raid4 after add new disks with mdadm --grow option.</issue>
  <issue tracker="jsc" id="SLE-10078"/>
  <issue tracker="jsc" id="SLE-9348"/>
  <issue tracker="bnc" id="1127526">[INTEL 15 SP1 BUG][VROC] Mdmon can corrupt IMSM metadata when rebooting during OS installation</issue>
  <issue tracker="bnc" id="1123814">device name in variable names is truncated</issue>
  <issue tracker="bnc" id="1115407">mdadm: migrate from cron to systemd timers</issue>
  <issue tracker="bnc" id="1139709">370 devices in a md array, it requires larger size buffer than the default hard coding value in systemd.</issue>
  <issue tracker="bnc" id="1153258">variable MDADM_CHECK_DURATION in /etc/sysconfig/mdadm is ignored</issue>
  <issue tracker="bnc" id="1126975">[INTEL 15 SP1 BUG][VROC] allow rebuild from double degraded array</issue>
  <issue tracker="bnc" id="1106078">[INTEL SLES12SP4 BUG] Compat symlinks break MD RAID autorebuild</issue>
  <issue tracker="bnc" id="1111960">Update SLE15-SP1 mdadm code base to 4.1</issue>
  <packager>colyli</packager>
  <rating>moderate</rating>
  <category>recommended</category>
  <summary>Recommended update for mdadm</summary>
  <description>This update for mdadm fixes the following issues:

- Fix for issue to avoid unexpected switching from raid0 to raid4 by using option '--grow'. (bsc#1129900)
- Add support for RAID0 layouts. (bsc#1162479)
- Enable mdadm to scan more than 6 operation ROMs. (bsc#1156040)
- Fix for finishing recovery when drive with rebuild fails. (bsc#1126975)
- Migrate cron jobs to system timer and implement systemd unit files. (bsc#1115407)
- Install mdadm environment script to 'usr/lib' (bsc#1111960)
- Fix for symlinks that may break MD RAID autorebuild. (bsc#1106078)
- Add '--no-devices' option for calling mdadm. (bsc#1139709)
- Fix for ignoring option 'MDADM_CHECK_DURATION' in systemd configuration. (bsc#1153258)
- Update SLE15-SP1 mdadm code base to 4.1. (bsc#1111960, jsc#SLE-10078, jsc#SLE-9348)
- Fix for md monitor that can corrupt metadata during reboot within OS installation (bsc#1127526)
- Fix for displaying wrong names in device names in listing. (bsc#1123814)
</description>
</patchinfo>