File nvme-cli.spec of Package nvme-cli.20931
#
# spec file for package nvme-cli
#
# Copyright (c) 2019 SUSE LINUX GmbH, Nuernberg, Germany.
#
# All modifications and additions to the file contributed by third parties
# remain the property of their copyright owners, unless otherwise agreed
# upon. The license for this file, and modifications and additions to the
# file, is the same license as for the pristine package itself (unless the
# license for the pristine package is not an Open Source License, in which
# case the license is the MIT License). An "Open Source License" is a
# license that conforms to the Open Source Definition (Version 1.9)
# published by the Open Source Initiative.
# Please submit bugfixes or comments via https://bugs.opensuse.org/
#
Name: nvme-cli
Version: 1.10
Release: 0
Summary: NVM Express user space tools
License: GPL-2.0-only
Group: Hardware/Other
URL: https://github.com/linux-nvme/nvme-cli
Source: %{name}-%{version}.tar.gz
Source2: nvme-cli-rpmlintrc
Patch1: 0001-Makefile-generate-Dracut-config-according-to-UDEVDIR.patch
Patch2: 0002-Makefile-use-UDEVRULESDIR-instead-of-UDEVDIR.patch
Patch3: 0003-Add-additional-smart-log-critical-warn-decoding.patch
Patch4: 0004-nvmf-autoconnect.service.patch
Patch5: 0005-nvme-cli-Add-script-to-determine-host-NQN.patch
Patch6: 0006-fabrics-write-reconnect_delay-to-fabrics-device-on-c.patch
Patch7: 0007-fabrics-set-keep_alive_tmo-also-for-discovery-controllers.patch
Patch8: 0008-fabrics-permit-kato-int-argument-for-discovery-controllers.patch
Patch9: 0009-fabrics-ensure-zero-kato-for-non-persistent-controllers.patch
Patch10: 0010-print-device-name-when-creating-a-persistent-device.patch
Patch11: 0011-nvme-add-fabrics-discovery-controller-default-port-n.patch
Patch12: 0012-fabrics-move-connect_args-extraction-to-a-dedicated-.patch
Patch13: 0013-nvme-discover-lookup-existing-persistent-controllers.patch
Patch14: 0014-nvme-topology-no-error-message-when-openeing-of-cont.patch
Patch15: 0015-nvme-ioctl-return-1-on-failure-from-nvme_get_nsid.patch
Patch16: 0016-nvme-topology-scan-all-controllers-in-scan_subsystem.patch
Patch17: 0017-connect-all-add-m-matching-option.patch
Patch18: 0018-fabrics-skip-connect-if-transport-type-doesn-t-match.patch
Patch19: 0019-nvme-topology-fix-controller-check-in-scan_subsystem.patch
Patch20: 0020-gen-hostnqn-Remove-UUID-validation-heuristic.patch
Patch21: 0021-nvme-print-fix-nvme-list-segfault-if-controller-is-u.patch
Patch22: 0022-fabrics-add-default-port-number-for-NVMe-TCP-I-O-con.patch
BuildRequires: asciidoc
BuildRequires: libuuid-devel
BuildRequires: xmlto
BuildRequires: pkgconfig
BuildRequires: pkgconfig(libudev)
BuildRequires: systemd-devel
%ifarch x86_64 aarch64 i586
Requires(post): dmidecode
%endif
%description
NVM Express (NVMe) is a direct attached storage interface. The
nvme-cli package contains core management tools with minimal
dependencies.
%package -n nvme-cli-regress-script
Summary: A small script to test the nvme binary for regressions
Group: Hardware/Other
Requires: nvme-cli
%description -n nvme-cli-regress-script
A small shell script to test the nvme binary for regressions. It requires an
NVMe device for testing purposes. Do NOT use in a production environment.
%prep
%setup -q
%patch1 -p1
%patch2 -p1
%patch3 -p1
%patch4 -p1
%patch5 -p1
%patch6 -p1
%patch7 -p1
%patch8 -p1
%patch9 -p1
%patch10 -p1
%patch11 -p1
%patch12 -p1
%patch13 -p1
%patch14 -p1
%patch15 -p1
%patch16 -p1
%patch17 -p1
%patch18 -p1
%patch19 -p1
%patch20 -p1
%patch21 -p1
%patch22 -p1
%build
echo %{version} > version
make CFLAGS="%{optflags} -I." PREFIX=%{_prefix} %{?_smp_mflags} all
# nvme-cli-regress-script subpackage: remove make and install steps
sed -i '/make.*/d' regress
%install
make PREFIX=%{_prefix} DESTDIR=%{buildroot} UDEVRULESDIR=%{_udevrulesdir} install-bin install-man install-udev install-systemd %{?_smp_mflags}
install -m 644 -D /dev/null %{buildroot}%{_sysconfdir}/nvme/hostnqn
install -m 644 -D completions/bash-nvme-completion.sh %{buildroot}%{_datadir}/bash_completion/completions/nvme
%ifarch x86_64 aarch64 i586
install -m 744 -D scripts/gen-hostnqn.sh %{buildroot}%{_sbindir}/nvme-gen-hostnqn
%endif
# for subpackage nvme-cli-regress-script:
install -m 744 -D regress %{buildroot}%{_sbindir}/nvme-regress
%define services nvmefc-boot-connections.service nvmf-connect.target nvmf-autoconnect.service
%pre
%service_add_pre %services nvmf-connect@.service
%post
%ifarch x86_64 aarch64 i586
if [ ! -s %{_sysconfdir}/nvme/hostnqn ]; then
%{_sbindir}/nvme-gen-hostnqn > %{_sysconfdir}/nvme/hostnqn
fi
%endif
if [ ! -s %{_sysconfdir}/nvme/hostnqn ]; then
%{_bindir}/echo "Generating random host NQN."
%{_sbindir}/nvme gen-hostnqn > %{_sysconfdir}/nvme/hostnqn
fi
if [ ! -s %{_sysconfdir}/nvme/hostid ]; then
%{_bindir}/uuidgen > %{_sysconfdir}/nvme/hostid
fi
%service_add_post %services nvmf-connect@.service
%preun
%service_del_preun -f %services
%postun
%service_del_postun %services
%posttrans
if [ -f /sys/class/fc/fc_udev_device/nvme_discovery ]; then
%{_bindir}/echo add > /sys/class/fc/fc_udev_device/nvme_discovery
fi
%files
%defattr(-,root,root)
%license LICENSE
%doc README.md
%{_sbindir}/nvme
%ifarch x86_64 aarch64 i586
%{_sbindir}/nvme-gen-hostnqn
%endif
%{_mandir}/man1/nvme*.1*%{?ext_man}
%dir %{_datadir}/bash_completion
%dir %{_datadir}/bash_completion/completions/
%{_datadir}/bash_completion/completions/nvme
%{_udevrulesdir}/70-nvmf-autoconnect.rules
%{_udevrulesdir}/71-nvmf-iopolicy-netapp.rules
%{_unitdir}/nvmefc-boot-connections.service
%{_unitdir}/nvmf-connect@.service
%{_unitdir}/nvmf-connect.target
%{_unitdir}/nvmf-autoconnect.service
%dir %{_sysconfdir}/nvme/
%ghost %{_sysconfdir}/nvme/hostnqn
%ghost %{_sysconfdir}/nvme/hostid
%files -n nvme-cli-regress-script
%defattr(-,root,root)
%{_sbindir}/nvme-regress
%changelog