File fe39e1b1-qemu-Adjust-max-memlock-on-mdev-hotplug.patch of Package libvirt.22292
commit fe39e1b181bbe10aa08868fc132315a569bfb730
Author: Eric Farman <farman@linux.ibm.com>
Date: Tue Sep 3 22:09:48 2019 +0200
qemu: Adjust max memlock on mdev hotplug
When starting a domain, we use the presence of a vfio-pci or
mdev hostdev to determine if the memlock maximum needs to be
increased. But if we hotplug either of these devices, only the
vfio-pci path gets that love. This means that attaching a, say,
vfio-ccw device will appear to succeed but the device may be
unusable as the guest may see I/O errors on long CCW chains.
The host, meanwhile, would be flooded with these messages:
vfio_pin_page_external: Task qemu-system-s39 (11584) RLIMIT_MEMLOCK (65536) exceeded
Let's adjust the maximum memlock value in the mdev hotplug path,
so that the domain has the same value as if it were started with
one or more mdev devices in its configuration.
Signed-off-by: Eric Farman <farman@linux.ibm.com>
Reviewed-by: Daniel Henrique Barboza <danielhb413@gmail.com>
Reviewed-by: Pavel Hrdina <phrdina@redhat.com>
Index: libvirt-5.1.0/src/qemu/qemu_hotplug.c
===================================================================
--- libvirt-5.1.0.orig/src/qemu/qemu_hotplug.c
+++ libvirt-5.1.0/src/qemu/qemu_hotplug.c
@@ -2991,6 +2991,7 @@ qemuDomainAttachMediatedDevice(virQEMUDr
bool teardowncgroup = false;
bool teardownlabel = false;
bool teardowndevice = false;
+ bool teardownmemlock = false;
qemuDomainObjPrivatePtr priv = vm->privateData;
virDomainDeviceDef dev = { VIR_DOMAIN_DEVICE_HOSTDEV,
{ .hostdev = hostdev } };
@@ -3034,6 +3035,10 @@ qemuDomainAttachMediatedDevice(virQEMUDr
if (VIR_REALLOC_N(vm->def->hostdevs, vm->def->nhostdevs + 1) < 0)
goto cleanup;
+ if (qemuDomainAdjustMaxMemLockHostdev(vm, hostdev) < 0)
+ goto cleanup;
+ teardownmemlock = true;
+
qemuDomainObjEnterMonitor(driver, vm);
ret = qemuMonitorAddDevice(priv->mon, devstr);
if (qemuDomainObjExitMonitor(driver, vm) < 0) {
@@ -3049,6 +3054,8 @@ qemuDomainAttachMediatedDevice(virQEMUDr
ret = 0;
cleanup:
if (ret < 0) {
+ if (teardownmemlock && qemuDomainAdjustMaxMemLock(vm) < 0)
+ VIR_WARN("Unable to reset maximum locked memory on hotplug fail");
if (teardowncgroup && qemuTeardownHostdevCgroup(vm, hostdev) < 0)
VIR_WARN("Unable to remove host device cgroup ACL on hotplug fail");
if (teardownlabel &&