File _patchinfo of Package patchinfo.7968

<patchinfo incident="7968">
  <issue id="1058538" tracker="bnc">nvme disconnect command-line inconsistency</issue>
  <issue id="1076113" tracker="bnc">[NetApp SLES12 SP3 Bug]: nvme-cli's list-ns --all option requests incorrect CNS</issue>
  <issue id="1076127" tracker="bnc">[NetApp SLES12 SP3 Bug]: nvme-cli's ns-descs option requests incorrect CNS</issue>
  <issue id="1076417" tracker="bnc">[NetApp SLES12 SP3 Bug]: return 0 if nvme-cli's disconnect operation with cfg.nqn is successful</issue>
  <issue id="1078032" tracker="bnc">nvme cli: add support for --ctrl-loss-tmo to connect command</issue>
  <issue id="1080672" tracker="bnc">nvme-cli: add NetApp plugin</issue>
  <category>recommended</category>
  <rating>low</rating>
  <packager>morbidrsa</packager>
  <description>This update for nvme-cli provides the following fix:

- Make it possible to pass the full device path when requesting the disconnection.
  (bsc#1058538)
- Return 0 if the disconnect command is successful. (bsc#1076417)
- Add ability to specify controller loss timeout when connecting. (bsc#1078032)
- Fix identifying active or allocated namespaces list. (bsc#1076113)
- Fix the "nvme ns-desc" command by making it request a CNS of 0x03 (Namespace descriptors)
  instead of a CNS of 0x13 (Controller list). (bsc#1076127)
- Add NetApp vendor plugin. (bsc#1080672)

This update was imported from the SUSE:SLE-12-SP3:Update update project.</description>
  <summary>Recommended update for nvme-cli</summary>
</patchinfo>