<patchinfo incident="29162">
<issue tracker="jsc" id="PED-3884"/>
<issue tracker="jsc" id="PED-553"/>
<issue tracker="bnc" id="1186689">[NetApp SLES15 SP4 RFE]: Make PDC the default option for targets that are TP 8013/8014 compliant</issue>
<issue tracker="bnc" id="1210105">[NetApp SLES15 SP4 Bug] NVMe/FC autoconnect scripts fail to parse config JSON file</issue>
<issue tracker="bnc" id="1207687">libnvme failed to build for s390x</issue>
<issue tracker="bnc" id="1209906">libnvme: nvme0 - Registration error. Result:0x0000, Status:0x4002 - Invalid Field in Command</issue>
<issue tracker="bnc" id="1209905">libnvme: Fix segmentation fault during garbage collection</issue>
<issue tracker="bnc" id="1207686">nvme-cli failed to build for s390x</issue>
<issue tracker="bnc" id="1210089">[NetApp SLES15 SP4 Bug] NVMe/FC config JSON file handling is broken</issue>
<issue tracker="bnc" id="1208001">[NetApp SLES15 SP4 Bug] Duplicate NVMe I/O controllers seen with nvme-stas when handling discovery AENs</issue>
<issue tracker="bnc" id="1208075">SLES15 SP5: lpar dropped into maintenance mode if nvmf mount point in /etc/fstab</issue>
<issue tracker="bnc" id="1211647">[Dell Storage SELES15SP5 BUG] Not all NBFT-defined NVMe connections are up after boot</issue>
<issue tracker="bnc" id="1207435">[NetApp SLES15 SP4 Bug] Invalid IP addresses in libnvme's python bindings file</issue>
<issue tracker="bnc" id="1209564">[NetApp SLES15 SP4 Bug]: nvme-read hits SGL error if block count option is omitted</issue>
<issue tracker="bnc" id="1209550">[NetApp SLES15 SP4 Bug] Misc fixes required for nvme supported-log-pages</issue>
<issue tracker="bnc" id="1208580">[NetApp SLES15 SP5 Bug] nvme-stas needs additional config options to apply in-band auth settings</issue>
<packager>wagi</packager>
<rating>moderate</rating>
<category>recommended</category>
<summary>Recommended update for libnvme, nvme-cli</summary>
<description>This update for libnvme, nvme-cli, nvme-stas fixes the following issues:
- Update to version v1.4 (jsc#PED-553, jsc#PED-3884)
- Fix invalid string lenght calculation for UUID (bsc#1209906)
- Fix segmentation fault during garbage collection (bsc#1209905)
- Always sanitize traddr and trsvcid entries (bsc#1207435)
- Allow tracking unique discover controllers (bsc#1186689)
- Enabled unit test on s390x again (bsc#1207687, bsc#1207686)
- Replaced old nbft implementation with the upstream one
- Don't enable TLS if kernel does not support it
- Set version-tag so that version are correctly reported
- Extend udev rule to pass --host-interface argument to nvme-cli (bsc#1208001)
- Build documentation to be up to date
- Improvements for supported-log-pages (bsc#1209550)
- Fix read command (bsc#1209564)
- Fix mounting filesystems via fstab (bsc#1208075)
- Update host_traddr when using config.json file (bsc#1210089)
- Changed default behavior of connect-all to match with old nbft behavior
- Fix auto connect conditions (bsc#1210105)
- Fix auto boot for NBFT connections (bsc#1211647)
- nvme-stas: Update to version 2.2:
- add DHCHAP support for in-band authentication (bsc#1208580)
</description>