From 7b8e72515f944a7b6a9171b6ca1d810d0b9f1f7b Mon Sep 17 00:00:00 2001 From: Tobias <tobias@codeatelier.com> Date: Fri, 15 Sep 2017 10:12:22 +0200 Subject: [PATCH 1/8] Add support for EUROtronic Spirit Z-wave Plus Thermostat --- config/eurotronic/eur_spiritz.xml | 83 +++++++++++++++++++++++++++++++++++++++ config/manufacturer_specific.xml | 1 + 2 files changed, 84 insertions(+) create mode 100644 config/eurotronic/eur_spiritz.xml diff --git a/config/eurotronic/eur_spiritz.xml b/config/eurotronic/eur_spiritz.xml new file mode 100644 index 000000000..ea038f1af --- /dev/null +++ b/config/eurotronic/eur_spiritz.xml @@ -0,0 +1,83 @@ +<?xml version="1.0" encoding="utf-8"?> +<Product xmlns='http://code.google.com/p/open-zwave/'> + <CommandClass id="67" base="0" typeInterpretation="A" /> + <CommandClass id="64" > + <Instance index="1" /> + <Value type="list" genre="user" instance="1" index="0" label="Mode"> + <Item label="Off" value="0" /> + <Item label="Heat" value="1" /> + <Item label="Heat Econ" value="11" /> + <Item label="Full Power" value="15" /> + <Item label="Manufacturer Specific" value="31" /> + </Value> + <SupportedModes> + <Mode index="0" label="Off" /> + <Mode index="1" label="Heat" /> + <Mode index="11" label="Heat Econ" /> + <Mode index="15" label="Full Power" /> + <Mode index="31" label="Manufacturer Specific" /> + </SupportedModes> + </CommandClass> + + <CommandClass id="112"> + <Value type="byte" genre="config" instance="1" index="1" label="Invert LCD" min="0" max="1" units="" value="0"> + <Help> + 0x00 LCD normal + 0x01 LCD inverted / upside down + Default: 0x00 + </Help> + </Value> + <Value type="byte" genre="config" instance="1" index="2" label="LCD Timeout" min="0" max="30" units="" value="0"> + <Help> + 0x00 No Timeout, LCD always on + 0x05-0x1E Timeout after 5 - 30s + default: 0x00 + </Help> + </Value> + <Value type="byte" genre="config" instance="1" index="3" label="Backlight" min="0" max="1" units="" value="1"> + <Help> + 0x00 No Backlight + 0x01 Backlight active + default: 0x01 + </Help> + </Value> + <Value type="byte" genre="config" instance="1" index="4" label="Battery Status" min="0" max="1" units="" value="1"> + <Help> + 0x00 Only send battery status as notification + 0x01 send battery status 1x daily + default: 0x01 + </Help> + </Value> + <Value type="byte" genre="config" instance="1" index="5" label="Temperature Report Threshold" min="0" max="50" units="°C" value="5"> + <Help> + 0x00 Don't send temperature automatically + 0x01 – 0x32 Report temperature at 0,1 - 5.0°C temperature difference + default 0x05 (Delta = 0,5°C ) + </Help> + </Value> + <Value type="byte" genre="config" instance="1" index="6" label="Valve Opening Degree" min="0" max="100" units="" value="0"> + <Help> + 0x00 Don't send Valve opening degree automatically + 0x01-0x64 report valve opening degree at a delta of 1 - 100%. + default 0x00 + </Help> + </Value> + <Value type="byte" genre="config" instance="1" index="7" label="Open Window Detection" min="0" max="3" units="" value="2"> + <Help> + 0x00 Disabled + 0x01 low sensibility + 0x02 medium sensibility + 0x03 high sensibility + default: 0x02 + </Help> + </Value> + <Value type="byte" genre="config" instance="1" index="8" label="Temperature Offset" min="-50" max="128" units="" value="0"> + <Help> + 0xCE-0x32 -5,0°C – (+)5,0°C + 0x80 External Temperature Sensor + default: 0x00 0,0°C Offset + </Help> + </Value> + </CommandClass> +</Product> + diff --git a/config/manufacturer_specific.xml b/config/manufacturer_specific.xml index 16769e9ff..30fcea76c 100644 --- a/config/manufacturer_specific.xml +++ b/config/manufacturer_specific.xml @@ -281,6 +281,7 @@ <Manufacturer id="0148" name="EUROtronic"> <Product type="0001" id="0001" name="EUR_STELLAZ Wall Radiator Thermostat Valve Control" config="eurotronic/eur_stellaz.xml"/> <Product type="0002" id="0001" name="EUR_COMETZ Wall Radiator Thermostat Valve Control" config="eurotronic/eur_cometz.xml"/> + <Product type="0003" id="0001" name="EUR_SPIRITZ Wall Radiator Thermostat" config="eurotronic/eur_spiritz.xml"/> </Manufacturer> <Manufacturer id="0128" name="Eneco"> <Product type="0000" id="0000" name="ED2.0 Meter Adapter"/> From 366aaf75cd82cb8f7fb9d45d08a1595d5aefbffe Mon Sep 17 00:00:00 2001 From: Kame <tobiasgraf@users.noreply.github.com> Date: Mon, 13 Nov 2017 10:29:06 +0100 Subject: [PATCH 2/8] Update eur_spiritz.xml Correct min. max for Temperature Offset --- config/eurotronic/eur_spiritz.xml | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/config/eurotronic/eur_spiritz.xml b/config/eurotronic/eur_spiritz.xml index ea038f1af..2e4464666 100644 --- a/config/eurotronic/eur_spiritz.xml +++ b/config/eurotronic/eur_spiritz.xml @@ -71,7 +71,7 @@ default: 0x02 </Help> </Value> - <Value type="byte" genre="config" instance="1" index="8" label="Temperature Offset" min="-50" max="128" units="" value="0"> + <Value type="byte" genre="config" instance="1" index="8" label="Temperature Offset" min="-128" max="50" units="" value="0"> <Help> 0xCE-0x32 -5,0°C – (+)5,0°C 0x80 External Temperature Sensor From 6bbc24631bedc704bb7649972d7eedecc4e75c1c Mon Sep 17 00:00:00 2001 From: Kame <tobiasgraf@users.noreply.github.com> Date: Thu, 16 Nov 2017 16:08:07 +0100 Subject: [PATCH 3/8] Add new product type ids for Eurotronic Spirit Z new Product Type ID for Eurotronic Spirit Z Radiator thermostat --- config/manufacturer_specific.xml | 3 +++ 1 file changed, 3 insertions(+) diff --git a/config/manufacturer_specific.xml b/config/manufacturer_specific.xml index 30fcea76c..9c9eba8b4 100644 --- a/config/manufacturer_specific.xml +++ b/config/manufacturer_specific.xml @@ -282,6 +282,9 @@ <Product type="0001" id="0001" name="EUR_STELLAZ Wall Radiator Thermostat Valve Control" config="eurotronic/eur_stellaz.xml"/> <Product type="0002" id="0001" name="EUR_COMETZ Wall Radiator Thermostat Valve Control" config="eurotronic/eur_cometz.xml"/> <Product type="0003" id="0001" name="EUR_SPIRITZ Wall Radiator Thermostat" config="eurotronic/eur_spiritz.xml"/> + <Product type="0003" id="0002" name="EUR_SPIRITZ Wall Radiator Thermostat" config="eurotronic/eur_spiritz.xml"/> + <Product type="0003" id="0003" name="EUR_SPIRITZ Wall Radiator Thermostat" config="eurotronic/eur_spiritz.xml"/> + </Manufacturer> </Manufacturer> <Manufacturer id="0128" name="Eneco"> <Product type="0000" id="0000" name="ED2.0 Meter Adapter"/> From 4e404ab84a4849dda705e9d11575a6e7608e561e Mon Sep 17 00:00:00 2001 From: Kame <tobiasgraf@users.noreply.github.com> Date: Mon, 20 Nov 2017 07:20:28 +0100 Subject: [PATCH 4/8] remove duplicate closing tag. --- config/manufacturer_specific.xml | 1 - 1 file changed, 1 deletion(-) diff --git a/config/manufacturer_specific.xml b/config/manufacturer_specific.xml index 9c9eba8b4..f9331f9af 100644 --- a/config/manufacturer_specific.xml +++ b/config/manufacturer_specific.xml @@ -285,7 +285,6 @@ <Product type="0003" id="0002" name="EUR_SPIRITZ Wall Radiator Thermostat" config="eurotronic/eur_spiritz.xml"/> <Product type="0003" id="0003" name="EUR_SPIRITZ Wall Radiator Thermostat" config="eurotronic/eur_spiritz.xml"/> </Manufacturer> - </Manufacturer> <Manufacturer id="0128" name="Eneco"> <Product type="0000" id="0000" name="ED2.0 Meter Adapter"/> <Product type="0128" id="0000" name="ED2.0 Display"/> From 01fb73505e756967ef4bd662247463988eecfa12 Mon Sep 17 00:00:00 2001 From: Daniel <epegzz@gmail.com> Date: Sat, 25 Nov 2017 05:04:50 +0100 Subject: [PATCH 5/8] Improve SpiritZ config --- config/eurotronic/eur_spiritz.xml | 123 +++++++++++++++++++++++--------------- distfiles.mk | 1 + 2 files changed, 76 insertions(+), 48 deletions(-) diff --git a/config/eurotronic/eur_spiritz.xml b/config/eurotronic/eur_spiritz.xml index 2e4464666..7d527fbc0 100644 --- a/config/eurotronic/eur_spiritz.xml +++ b/config/eurotronic/eur_spiritz.xml @@ -1,83 +1,110 @@ <?xml version="1.0" encoding="utf-8"?> +<!-- +Eurotronic Spirit Z-Wave Plus Thermostat +Product website: https://www.eurotronic.org/produkte/spirit-z-wave-plus.html +Tech manual: https://www.eurotronic.org/fileadmin/user_upload/eurotronic.org/Produktbilder/spirit_z_wave_plus/Spirit_Z-Wave_BAL_web_EN_view_04.pdf +--> <Product xmlns='http://code.google.com/p/open-zwave/'> - <CommandClass id="67" base="0" typeInterpretation="A" /> - <CommandClass id="64" > + <!-- Multilevel switch for setting valve opening --> + <CommandClass id="38"> + <Value type="byte" genre="user" index="0" label="Valve Opening" units="%" min="0" max="100" value="0" /> + </CommandClass> + + <!-- Thermostat mode --> + <CommandClass id="64"> <Instance index="1" /> <Value type="list" genre="user" instance="1" index="0" label="Mode"> - <Item label="Off" value="0" /> - <Item label="Heat" value="1" /> - <Item label="Heat Econ" value="11" /> - <Item label="Full Power" value="15" /> - <Item label="Manufacturer Specific" value="31" /> + <Help> + Off: No heating, only frost protection. + Auto: Room temperature will be kept at the configured setpoint. + Eco: Energy save heating mode. Room temperature will be lowered to the configured eco setpoint in order to save energy. + Full Power: Full power heating. This mode is left automatically after 5 minutes. + Manufacturer Specific: Direct valve control mode. The valve opening percentage can be controlled using the switch multilevel command class. + </Help> + <Item label="Off" value="0" /> + <Item label="Auto" value="1" /> + <Item label="Eco" value="11" /> + <Item label="Full Power" value="15" /> + <Item label="Manufacturer Specific" value="31" /> </Value> <SupportedModes> - <Mode index="0" label="Off" /> - <Mode index="1" label="Heat" /> - <Mode index="11" label="Heat Econ" /> - <Mode index="15" label="Full Power" /> - <Mode index="31" label="Manufacturer Specific" /> + <Mode index="0" label="Off" /> + <Mode index="1" label="Auto" /> + <Mode index="11" label="Eco" /> + <Mode index="15" label="Full Power" /> + <Mode index="31" label="Manufacturer Specific" /> </SupportedModes> </CommandClass> + <!-- Setpoints --> + <CommandClass id="67" base="0" typeInterpretation="A"> + <Instance index="1"/> + <Value type="decimal" genre="user" instance="1" index="1" label="Target Temperature" units="°C" read_only="false" write_only="false" min="8" max="28" value="20"/> + <Value type="decimal" genre="user" instance="1" index="11" label="Target Temperature Eco" units="°C" read_only="false" write_only="false" min="8" max="28" value="16"/> + </CommandClass> + + <!-- Configuration Parameters --> <CommandClass id="112"> - <Value type="byte" genre="config" instance="1" index="1" label="Invert LCD" min="0" max="1" units="" value="0"> + <Instance index="1"/> + <Value type="list" genre="config" instance="1" index="1" label="LCD Invert" min="0" max="1" value="0" size="1"> <Help> - 0x00 LCD normal - 0x01 LCD inverted / upside down - Default: 0x00 + Allows rotating the LCD contents by 180 degrees. + Default: Normal </Help> + <Item label="Normal" value="0" /> + <Item label="Upside Down" value="1" /> </Value> - <Value type="byte" genre="config" instance="1" index="2" label="LCD Timeout" min="0" max="30" units="" value="0"> + <Value type="byte" genre="config" instance="1" index="2" label="LCD Timeout" min="0" max="30" units="sec" value="0"> <Help> - 0x00 No Timeout, LCD always on - 0x05-0x1E Timeout after 5 - 30s - default: 0x00 + 0: No Timeout, LCD always on. + 5-30: Timeout after 5-30s. + Default: 0 (LCD always on) </Help> </Value> - <Value type="byte" genre="config" instance="1" index="3" label="Backlight" min="0" max="1" units="" value="1"> + <Value type="list" genre="config" instance="1" index="3" label="Backlight" min="0" max="1" units="" value="1" size="1"> <Help> - 0x00 No Backlight - 0x01 Backlight active - default: 0x01 + Default: Backlight enabled </Help> + <Item label="Backlight disabled" value="0" /> + <Item label="Backlight enabled" value="1" /> </Value> - <Value type="byte" genre="config" instance="1" index="4" label="Battery Status" min="0" max="1" units="" value="1"> + <Value type="list" genre="config" instance="1" index="4" label="Battery Report" min="0" max="1" units="" value="1" size="1"> <Help> - 0x00 Only send battery status as notification - 0x01 send battery status 1x daily - default: 0x01 + Default: Send once a day </Help> + <Item label="Only send battery status as notification" value="0" /> + <Item label="Send once a day" value="1" /> </Value> - <Value type="byte" genre="config" instance="1" index="5" label="Temperature Report Threshold" min="0" max="50" units="°C" value="5"> + <Value type="byte" genre="config" instance="1" index="5" label="Temperature Report Threshold" min="0" max="50" units="0.1°C" value="5"> <Help> - 0x00 Don't send temperature automatically - 0x01 – 0x32 Report temperature at 0,1 - 5.0°C temperature difference - default 0x05 (Delta = 0,5°C ) + 0: Don't send temperature automatically. + 1-50: Report temperature at 0.1-5.0°C temperature difference. + Default: 5 (Delta = 0.5°C) </Help> </Value> - <Value type="byte" genre="config" instance="1" index="6" label="Valve Opening Degree" min="0" max="100" units="" value="0"> + <Value type="byte" genre="config" instance="1" index="6" label="Valve Opening Percentage Report" min="0" max="100" units="" value="0"> <Help> - 0x00 Don't send Valve opening degree automatically - 0x01-0x64 report valve opening degree at a delta of 1 - 100%. - default 0x00 + 0: Don't send Valve opening percentage automatically. + 1-100: Report valve opening percentage at a delta of 1-100%. + Default: 0 </Help> - </Value> - <Value type="byte" genre="config" instance="1" index="7" label="Open Window Detection" min="0" max="3" units="" value="2"> + </Value> + <Value type="list" genre="config" instance="1" index="7" label="Open Window Detection" min="0" max="3" units="" value="2" size="1"> <Help> - 0x00 Disabled - 0x01 low sensibility - 0x02 medium sensibility - 0x03 high sensibility - default: 0x02 + Default: Medium sensibility </Help> + <Item label="Disabled" value="0" /> + <Item label="Low sensibility" value="1" /> + <Item label="Medium sensibility" value="2" /> + <Item label="High sensibility" value="3" /> </Value> - <Value type="byte" genre="config" instance="1" index="8" label="Temperature Offset" min="-128" max="50" units="" value="0"> + <Value type="byte" genre="config" instance="1" index="8" label="Measured Temperature Offset" min="0" max="255" units="" value="0"> <Help> - 0xCE-0x32 -5,0°C – (+)5,0°C - 0x80 External Temperature Sensor - default: 0x00 0,0°C Offset + 206-255: -5.0 to -0.1°C. + 0-50: 0°C-5°C. + 128: External Temperature Sensor. + Default: 0 (0.0°C Offset) </Help> </Value> </CommandClass> </Product> - diff --git a/distfiles.mk b/distfiles.mk index 96f1a7552..7b2eb162c 100644 --- a/distfiles.mk +++ b/distfiles.mk @@ -102,6 +102,7 @@ DISTFILES = .gitignore \ config/enerwave/zwn-bpc.xml \ config/enerwave/zwn-sc7.xml \ config/eurotronic/eur_cometz.xml \ + config/eurotronic/eur_spiritz.xml \ config/eurotronic/eur_stellaz.xml \ config/everspring/ad146.xml \ config/everspring/ad147.xml \ From f2edddac68411045ed820fcf2c3bb1547b5dd7e4 Mon Sep 17 00:00:00 2001 From: Daniel <epegzz@gmail.com> Date: Mon, 27 Nov 2017 19:38:29 +0100 Subject: [PATCH 6/8] Don't update disfiles.mk --- distfiles.mk | 1 - 1 file changed, 1 deletion(-) diff --git a/distfiles.mk b/distfiles.mk index 7b2eb162c..96f1a7552 100644 --- a/distfiles.mk +++ b/distfiles.mk @@ -102,7 +102,6 @@ DISTFILES = .gitignore \ config/enerwave/zwn-bpc.xml \ config/enerwave/zwn-sc7.xml \ config/eurotronic/eur_cometz.xml \ - config/eurotronic/eur_spiritz.xml \ config/eurotronic/eur_stellaz.xml \ config/everspring/ad146.xml \ config/everspring/ad147.xml \ From f91ae0affe02a9e1b1822a6c9964cd4b48cd2a6d Mon Sep 17 00:00:00 2001 From: Daniel <epegzz@gmail.com> Date: Mon, 27 Nov 2017 19:40:42 +0100 Subject: [PATCH 7/8] Use mode/setpoint naming according to specs --- config/eurotronic/eur_spiritz.xml | 16 ++++++++-------- 1 file changed, 8 insertions(+), 8 deletions(-) diff --git a/config/eurotronic/eur_spiritz.xml b/config/eurotronic/eur_spiritz.xml index 7d527fbc0..3500ac5ca 100644 --- a/config/eurotronic/eur_spiritz.xml +++ b/config/eurotronic/eur_spiritz.xml @@ -16,21 +16,21 @@ Tech manual: https://www.eurotronic.org/fileadmin/user_upload/eurotronic.org/Pro <Value type="list" genre="user" instance="1" index="0" label="Mode"> <Help> Off: No heating, only frost protection. - Auto: Room temperature will be kept at the configured setpoint. - Eco: Energy save heating mode. Room temperature will be lowered to the configured eco setpoint in order to save energy. + Heat: Room temperature will be kept at the configured setpoint. + Heat Eco: Energy save heating mode. Room temperature will be lowered to the configured eco setpoint in order to save energy. Full Power: Full power heating. This mode is left automatically after 5 minutes. Manufacturer Specific: Direct valve control mode. The valve opening percentage can be controlled using the switch multilevel command class. </Help> <Item label="Off" value="0" /> - <Item label="Auto" value="1" /> - <Item label="Eco" value="11" /> + <Item label="Heat" value="1" /> + <Item label="Heat Eco" value="11" /> <Item label="Full Power" value="15" /> <Item label="Manufacturer Specific" value="31" /> </Value> <SupportedModes> <Mode index="0" label="Off" /> - <Mode index="1" label="Auto" /> - <Mode index="11" label="Eco" /> + <Mode index="1" label="Heat" /> + <Mode index="11" label="Heat Eco" /> <Mode index="15" label="Full Power" /> <Mode index="31" label="Manufacturer Specific" /> </SupportedModes> @@ -39,8 +39,8 @@ Tech manual: https://www.eurotronic.org/fileadmin/user_upload/eurotronic.org/Pro <!-- Setpoints --> <CommandClass id="67" base="0" typeInterpretation="A"> <Instance index="1"/> - <Value type="decimal" genre="user" instance="1" index="1" label="Target Temperature" units="°C" read_only="false" write_only="false" min="8" max="28" value="20"/> - <Value type="decimal" genre="user" instance="1" index="11" label="Target Temperature Eco" units="°C" read_only="false" write_only="false" min="8" max="28" value="16"/> + <Value type="decimal" genre="user" instance="1" index="1" label="Heat" units="°C" read_only="false" write_only="false" min="8" max="28" value="20"/> + <Value type="decimal" genre="user" instance="1" index="11" label="Heat Eco" units="°C" read_only="false" write_only="false" min="8" max="28" value="16"/> </CommandClass> <!-- Configuration Parameters --> From 6d9d94640bf200e613378db8ff4d6f220e9b6da0 Mon Sep 17 00:00:00 2001 From: diman1234 <diman1234@git.git> Date: Fri, 29 Dec 2017 23:13:37 +0100 Subject: [PATCH 8/8] Updated the config file to new dev branch format. --- config/device_configuration.xsd | 1 + config/eurotronic/eur_spiritz.xml | 2 +- 2 files changed, 2 insertions(+), 1 deletion(-) diff --git a/config/device_configuration.xsd b/config/device_configuration.xsd index e4621ac49..6290926fa 100644 --- a/config/device_configuration.xsd +++ b/config/device_configuration.xsd @@ -69,6 +69,7 @@ <xs:attribute name='base' type='xs:string' use='optional'/> <xs:attribute name='override_precision' type='xs:string' use='optional'/> <xs:attribute name='scenecount' type='xs:string' use='optional'/> + <xs:attribute name='typeInterpretation' type='xs:string' use='optional'/> <xs:attribute name='create_vars' use='optional'> <xs:simpleType> <xs:restriction base='xs:string'> diff --git a/config/eurotronic/eur_spiritz.xml b/config/eurotronic/eur_spiritz.xml index 3500ac5ca..abe45c189 100644 --- a/config/eurotronic/eur_spiritz.xml +++ b/config/eurotronic/eur_spiritz.xml @@ -4,7 +4,7 @@ Eurotronic Spirit Z-Wave Plus Thermostat Product website: https://www.eurotronic.org/produkte/spirit-z-wave-plus.html Tech manual: https://www.eurotronic.org/fileadmin/user_upload/eurotronic.org/Produktbilder/spirit_z_wave_plus/Spirit_Z-Wave_BAL_web_EN_view_04.pdf --> -<Product xmlns='http://code.google.com/p/open-zwave/'> +<Product xmlns='https://github.com/OpenZWave/open-zwave' Revision="1"> <!-- Multilevel switch for setting valve opening --> <CommandClass id="38"> <Value type="byte" genre="user" index="0" label="Valve Opening" units="%" min="0" max="100" value="0" />
Locations
Projects
Search
Status Monitor
Help
OpenBuildService.org
Documentation
API Documentation
Code of Conduct
Contact
Support
@OBShq
Terms
openSUSE Build Service is sponsored by
The Open Build Service is an
openSUSE project
.
Sign Up
Log In
Places
Places
All Projects
Status Monitor