Oscilloscope Software for Syscomp CircuitGear CGR-101

Edit Package syscomp-cgr
http://www.syscompdesign.com/download.html

The software for the instrument graphical user interfaces is maintained as part
of the Open Instrumentation Project. The source code is licensed under the GPL,
and the current revisions can be found on https://sourceforge.net/projects/oip

SysComp CGR101 is an oscilloscope, waveform generator, and digital I/O port
integrated into one small, low cost unit.

* 20MS/s dual channel, 10-bit oscilloscope
* 2 MHz DDS arbitrary waveform generator
* Eight channel digital I/O
* USB powered, no AC adaptor required
* Open source software for Windows, Linux and Mac

Refresh
Refresh
Source Files
Filename Size Changed
CGR101V112.patch 0000003699 3.61 KB
CGR101V112.zip 0004333355 4.13 MB
CGR101V114.patch 0000007188 7.02 KB
CGR101V114.zip 0014082117 13.4 MB
icue-2006.pdf 0000095193 93 KB
relay-demo.pdf 0000207642 203 KB
scope-specs.pdf 0000370048 361 KB
syscomp-cgr 0000000806 806 Bytes
syscomp-cgr.changes 0000002868 2.8 KB
syscomp-cgr.spec 0000003341 3.26 KB
update_pkg.pl 0000007493 7.32 KB
Revision 22 (latest revision is 28)
Juergen Weigert's avatar Juergen Weigert (jnweiger) committed (revision 22)
- updated to 1.14, found all missing source dependencies at sourceforge.
- Tossed all precompiled binaries. 
- My old patch is still needed so that it can be installed and called from a
  different directory than the source. Config files are in ~/.syscomp-cgr/, doc
  files in %{docdir}, and user files in the current directory. 
- main.tcl used 'see' ???; wavemaker.tcl used [xpdf evince acroread] for 
  opening pdf-manuals. Prefer the more universal wrapper xdg-open.

- Version 1.14 - May 2010
  ----------------------------
  -changed ordering of tools menu so that the calibration tools are grouped together
  -removed disable checkbox on vertical controls and added options menus
  -added waveform inversion option for both channels
  -added on-screen label indicators for inversion and channel disabled
  -added option to switch on/off scientific notation in network analyzer to view menu in NA
  -added a check button to the help menu to disable checking for updates on startup
  -added PDF manual to help menu
  -fixed bug when launching waveMaker manual under Windows
  -fixed bug in data recorder that would prevent all 1024 samples from being recorded
  -fixed bug in data recorder where all column headings were being entered in the first column
  -user can now right-click on the phase plot in network analyzer mode to select the phase range displayed on the y-axis
  -fixed bug in XY mode where slope was inverted
  -fixed a bug where switching from auto triggering to external triggering would cause external triggering to stop working
  -added feature where the left and right arrow keys now scroll the FFT cursor by one pixel
  -added this change log to the help menu and reordered the menu

- Version 1.13 - December 2009
  ----------------------------
  -added a command to the view menu that lets the user float the digital I/O controls in a separate window
  -added WaveMaker utility to the tools menu
  -added export to CSV function for network analyzer