ICC compatible color management system

Edit Package argyllcms
http://www.%{name}.com/

The Argyll color management system supports accurate ICC profile creation for
scanners, CMYK printers, film recorders and calibration and profiling of
displays.

Spectral sample data is supported, allowing a selection of illuminants observer
types, and paper fluorescent whitener additive compensation. Profiles can also
incorporate source specific gamut mappings for perceptual and saturation
intents. Gamut mapping and profile linking uses the CIECAM02 appearance model,
a unique gamut mapping algorithm, and a wide selection of rendering intents. It
also includes code for the fastest portable 8 bit raster color conversion
engine available anywhere, as well as support for fast, fully accurate 16 bit
conversion. Device color gamuts can also be viewed and compared using a VRML
viewer.

Refresh
Refresh
Source Files
Filename Size Changed
19-color.fdi 0000004859 4.75 KB
Argyll_V3.0.0_src.zip 0014186686 13.5 MB
ajam-2.5.2-1.3.3.tgz 0000258260 252 KB
ajam-include.patch 0000001293 1.26 KB
argyllcms.changes 0000034588 33.8 KB
argyllcms.spec 0000005027 4.91 KB
color-device-file.policy 0000000658 658 Bytes
Revision 29 (latest revision is 33)
Ana Guerrero's avatar Ana Guerrero (anag+factory) accepted request 1113752 from Antonio Teixeira's avatar Antonio Teixeira (ateixeira) (revision 29)
- Update to 3.0.0:
  * Updated ccast/axTLS to get ChromCast working again with latest Google CC
    operating software.
  * Extensive re-write/re-factor of icclib to make it more future-proof.
    See https://www.argyllcms.com/doc/ChangesSummary.html for details.
  * Added ref/ColorCheckerPassport.ti2 and ref/ColorCheckerHalfPassport.ti2
    to allow measuring ColorCheckerPassport with instrument.
  * Fixed bug in Munki spectro hi-res mode with some instruments. Luminance
    matching between normal and hi-res was sometimes quite poor.
  * Added ARGYLL_CREATE_DISPLAY_PROFILE_WITHOUT_CHAD environment variable.
  * Changed colprof -U flag to -u. Changed dispcal -J flag to -K to accommodate
    a potential new flag for colprof and dispcal.
  * Added workaround for bug in madHcNet64.dll32/64.dll which sometimes causes
    failure.
  * Added delay after USB set_config on OS X to help Spyder 3/4 on Ventura OS.
  * Added -Y parameter to dispwin to override automatic patch delay.
  * Changed i1d3 driver to cope with Rev. B "0x83" error robustly. This should 
    fix any issues measuring low level Red only patch values on OLED displays,
    but with slower measurements when this occurs.
  * Added spotread -Y S option to save spectral sensitivity curves and added
    corresponding support in i1d3 driver. This allows for comparison of different
    instruments factory calibrations.
  * Added a -h scale parameter to dispread, to allow the automatic instrument
    calibration test patch values to be scaled down from their default 100%
    value. This is useful with HDR displays.
  * Added manifest to MSWindows executables to use UTF-8 code pages on Windows
    1903 and later. This should improve non-ASCII filename and path handling.
  * Added a Violet colorant to the targen colorant list.
  * Fixed problem with OS X 64 bit backwards compatibility where it failed to
    locate serial instruments when the binaries are run on OS X V12 or latter
    machines.
  * Fixed bug in i1Pro3 driver where it was not returning the correct
    measurement conditions enum.
  * Fixed spotread so that ambient measure for monochrome sources doesn't error
    out due to bad CCT/VCT/VDT. Also change -T so that it suppresses CCT etc. if
    ambient mode is used.
  * Added hacky workaround to strange Mac M2/rosetta bug in del_i1proimp().
- Make the argyllcms-doc package noarch.
Comments 0
openSUSE Build Service is sponsored by