Recommended update for nvme-cli

nvme-cli was updated to fix the following issues:

- Do not print error message when opening controller (bsc#1186719)
- Fix failures during 'nvme list' (bsc#1186719)
- Only connect to matching controllers (bsc#1186719)
- Skip connect if transport type doesn't match (bsc#1187287 bsc#1187860)
- Ignore non live controllers when scanning subsystems (bsc#1186719 bsc#1187287)
- Remove UUID validation heuristic (bsc#1187890)
- Do not segfault when controller is not available (bsc#1189046)
- Use correct default port for discovery (bsc#1189195 bsc#1187858)

This update was imported from the SUSE:SLE-15-SP2:Update update project.

Fixed bugs
bnc#1186719
[NetApp SLES15 SP3 Bug]: 'nvme list' errors when paths are down
bnc#1187287
[NetApp SLES15 SP2 Bug]: connect errors seen if discovery log page data contains records belonging to multiple transport types
bnc#1187858
"nvme connect" uses port 8009 by default and is rejected by the storage array
bnc#1187860
"Invalid argument" when running "nvme connect-all"
bnc#1187890
nvme-gen-hostnqn flags system UUID as too repetitive leading to NVMe BFS failure
bnc#1189046
[NetApp SLES15 SP3 Bug]: 'nvme list' seg faults if controller is not available
bnc#1189195
[NetApp SLES15 SP3 Bug]: Add default port number for NVMe/TCP I/O controllers