Recommended update for nvme-cli

This update for nvme-cli provides the following fix:

- Make it possible to pass the full device path when requesting the disconnection.
(bsc#1058538)
- Return 0 if the disconnect command is successful. (bsc#1076417)
- Add ability to specify controller loss timeout when connecting. (bsc#1078032)
- Fix identifying active or allocated namespaces list. (bsc#1076113)
- Fix the "nvme ns-desc" command by making it request a CNS of 0x03 (Namespace descriptors)
instead of a CNS of 0x13 (Controller list). (bsc#1076127)
- Add NetApp vendor plugin. (bsc#1080672)

This update was imported from the SUSE:SLE-12-SP3:Update update project.

Fixed bugs
bnc#1058538
nvme disconnect command-line inconsistency
bnc#1076113
[NetApp SLES12 SP3 Bug]: nvme-cli's list-ns --all option requests incorrect CNS
bnc#1076127
[NetApp SLES12 SP3 Bug]: nvme-cli's ns-descs option requests incorrect CNS
bnc#1076417
[NetApp SLES12 SP3 Bug]: return 0 if nvme-cli's disconnect operation with cfg.nqn is successful
bnc#1078032
nvme cli: add support for --ctrl-loss-tmo to connect command
bnc#1080672
nvme-cli: add NetApp plugin
Selected Binaries
openSUSE Build Service is sponsored by