Overview

Request 340388 accepted

- vesion 0.6.27
- spec: disabled teamd support for SLE-12-GA/13.2, not available
- nanny: fix policy file reading and objects references (boo#916035)
- ovs: use --may-exist option in add-port (bsc#951315) commands to
avoid error messages when the port is already in the db.
- netconfig: do not refresh unrelated details in supplicants
- service: fixed wicked client and nanny dependencies (bsc#950333).
- service: restart wickedd* on dbus restart (bsc#941964)
- fsm: do not follow link-up checks on configured master devices
not involved in the current ifup operation (bsc#948423).
- client: added more comfortable "wicked test dhcp[46]" commands
executing the wickedd-dhcp[46] in their --test mode (bsc#942278)

- version 0.6.26
- nanny: add link device references to policy match (bsc#941611)
This causes, that nanny checks and waits until the configuration
for link references is applied by ifup (master device worker is
available) in order to not start managing ports/slaves and fail
on unresolvable requirements with "document error" first.
Unavailable reference matches caused a timing race, where nanny
omits to enslave ports into master (e.g. a dummy into ovsbr),
but was not limited to ovs setups.
- dhcp4: fix to request offer by default in --test (bsc#942278)
- teamd: adjust permissions of the teamd interface config to be
owned by teamd user if available and to always re-read dbus
busname from the service file (bsc#947542)

- version 0.6.25
- compat: read complete sysctl file set (bsc#928459)
- wireless: fixed to parse/format hex escapes in essid (bsc#928459)

Loading...
Request History
Marius Tomaschewski's avatar

mtomaschewski created request

- vesion 0.6.27
- spec: disabled teamd support for SLE-12-GA/13.2, not available
- nanny: fix policy file reading and objects references (boo#916035)
- ovs: use --may-exist option in add-port (bsc#951315) commands to
avoid error messages when the port is already in the db.
- netconfig: do not refresh unrelated details in supplicants
- service: fixed wicked client and nanny dependencies (bsc#950333).
- service: restart wickedd* on dbus restart (bsc#941964)
- fsm: do not follow link-up checks on configured master devices
not involved in the current ifup operation (bsc#948423).
- client: added more comfortable "wicked test dhcp[46]" commands
executing the wickedd-dhcp[46] in their --test mode (bsc#942278)

- version 0.6.26
- nanny: add link device references to policy match (bsc#941611)
This causes, that nanny checks and waits until the configuration
for link references is applied by ifup (master device worker is
available) in order to not start managing ports/slaves and fail
on unresolvable requirements with "document error" first.
Unavailable reference matches caused a timing race, where nanny
omits to enslave ports into master (e.g. a dummy into ovsbr),
but was not limited to ovs setups.
- dhcp4: fix to request offer by default in --test (bsc#942278)
- teamd: adjust permissions of the teamd interface config to be
owned by teamd user if available and to always re-read dbus
busname from the service file (bsc#947542)

- version 0.6.25
- compat: read complete sysctl file set (bsc#928459)
- wireless: fixed to parse/format hex escapes in essid (bsc#928459)


Maintenance Bot's avatar

maintbot accepted review

accepted


Maintenance Bot's avatar

maintbot approved review

accepted


Jens Mammen's avatar

jmammen accepted request

Thanks.